PCDD/F Emissions During Startup and Shutdown of a Hazardous Waste Incinerator.

Min Li,Chao Wang,Kefa Cen,Mingjiang Ni,Xiaodong Li
DOI: https://doi.org/10.1016/j.chemosphere.2017.04.044
IF: 8.8
2017-01-01
Chemosphere
Abstract:Compared with municipal solid waste incineration, studies on the PCDD/F emissions of hazardous waste incineration (HWI) under transient conditions are rather few. This study investigates the PCDD/F emission level, congener profile and removal efficiency recorded during startup and shutdown by collecting flue gas samples at the bag filter inlet and outlet and at the stack. The PCDD/F concentration measured in the stack gas during startup and shutdown were 0.56-4.16 ng I-TEQ Nm(-3) and 1.09-336 ng I-TEQ Nm(-3), respectively, far exceeding the present codes in China. The total amount of PCDD/F emissions, resulting from three shutdown-startup cycles of this HWI-unit is almost equal to that generated during one year under normal operating conditions. Upstream the filter, the PCDD/F in the flue gas is mainly in the particle phase; however, after being filtered PCDD/F prevails in the gas phase. The PCDD/F fraction in the gas phase even exceeds 98% after passing through the alkaline scrubber. Especially higher chlorinated PCDD/F accumulate on inner walls of filters and ducts during these startup periods and could be released again during normal operation, significantly increasing PCDD/F emissions. (C) 2017 Published by Elsevier Ltd.
What problem does this paper attempt to address?