Study on the Application of Virtual Touch Tissue Imaging Quantification in Combination With the 2015 Guidelines of American Thyroid Association for Differentiating Benign Thyroid Nodules From Malignant Thyroid Nodules
毛锋,徐辉雄,张盛敏,张一峰,伯小皖,李小龙,李丹丹,刘博姬,徐军妹
DOI: https://doi.org/10.3969/j.issn.1007-9572.2016.21.019
2016-01-01
Abstract:Objective To assess the clinical application value of virtual touch tissue imaging quantification(VTIQ) in combination with the 2015 guidelines of American Thyroid Association(ATA)for differentiating benign thyroid nodules from malignant thyroid nodules. Methods 109 patients with thyroid nodules in the Tenth People’ s Hospital Affiliated to Tongji University from May to November in 2015,were selected as study subjects,109 thyroid nodules were confirmed by pathology after surgery. Patients underwent conventional ultrasonic examinations and VTIQ examinations,and were grouped according to the 2015 guidelines of ATA. Histopathological examination results were the gold standard,the values of simple application of VTIQ, simple application of 2015 guidelines of ATA,and application of VTIQ in combination with 2015 guidelines of ATA for differentiating malignant thyroid nodules from benign thyroid nodules were compared. Results There were 65 benign thyroid nodules and 44 malignant thyroid nodules among 109 thyroid nodules. There was not significant difference in diameter between benign thyroid nodules and malignant thyroid nodules( P ﹥ 0. 05);there were significant differences in ingredient,echo, nodule edge,calcification and aspect ratio between benign thyroid nodules and malignant thyroid nodules( P ﹤ 0. 001). The maximum value of SWS,the minimum value of SWS,and the average value of SWS of benign thyroid nodules were all lower than those of malignant thyroid nodules(P ﹤ 0. 001). There was significant difference in 2015 guidelines of ATA grouping situation between benign thyroid nodules and malignant thyroid nodules( P ﹤ 0. 001). For differentiating benign thyroid nodules from malignant thyroid nodules,the areas under the ROC curves(AUC)for the maximum value of SWS,the minimum value of SWS and the average value of SWS was 0. 834〔95% CI(0. 758,0. 911)〕,0. 841〔95% CI(0. 763,0. 919)〕and 0. 861〔95%CI(0. 790,0. 933)〕,respectively,the diagnostic cut - off value was 3. 26,2. 54 and 2. 92 m/ s,respectively. With a cut -off value of 2. 92 m/ s,the sensitivity,specificity and accuracy of the average value of SWS were 79. 5% (35 / 44),83. 1%(54 / 65)and 81. 7% (89 / 109),respectively. Cases in very low suspicious malignant group were diagnosed with benign thyroid nodules,cases in low suspicious malignant group and above( including no description group) were diagnosed with malignant thyroid nodules,the sensitivity,specificity and accuracy was 97. 7% (43 / 44),40. 0% (26 / 65) and 63. 3% (69 / 109) respectively in differentiating malignant thyroid nodules from benign thyroid nodules,the AUC was 0. 689〔95% CI(0. 591, 0. 786)〕. Cases in very low suspicious malignant group were diagnosed with benign thyroid nodules,cases in highly suspicious for malignancy group were diagnosed with malignant thyroid nodules;for low - grade,moderate suspicious malignant group and no description group,the diagnosis of benign thyroid nodules was made according to the SWS average value ﹤ 2. 92 m/ s,and the diagnosis of malignant thyroid nodules was made according to the SWS average value≥2. 92 m/ s. The sensitivity,specificity and accuracy of VTIQ in combination with the 2015 guidelines of ATA in the diagnosis of benign thyroid nodules and malignant thyroid nodules was 97. 7% (43 / 44),80. 0% (52 / 65),87. 2% (95 / 109),respectively,the AUC was 0. 889〔95% CI(0. 824, 0. 954)〕. The sensitivity of VTIQ in combination with the 2015 guidelines of ATA was equal to simple application of 2015 guidelines of ATA,while the specificity and accuracy of VTIQ in combination with the 2015 guidelines of ATA were significantly higher than those of simple application of 2015 guidelines of ATA,respectively( P ﹤ 0. 001). The sensitivity of VTIQ in combination with the 2015 guidelines of ATA was significantly higher than that of simple application of VTIQ(P = 0. 008),there was no significant difference in the specificity and accuracy between VTIQ in combination with the 2015 guidelines of ATA and VTIQ(P = 0. 727,P = 0. 210). Conclusion VTIQ is an important method for differentiating malignant thyroid nodules from benign thyroid nodules. Compared with simple application of 2015 guidelines of ATA,application of VTIQ in combination with 2015 guidelines of ATA can improve the specificity and accuracy of thyroid nodules diagnosis without loss of sensitivity.