Value of virtual touch tissue imaging quantification in differentiating benign and malignant thyroid nodules

Yan-fang LI,Hui-xiong XU,Yi-feng ZHANG,Jun-mei XU,Xiao-wan BO,Dan-dan LI,Kai-rong LEI,Lin FANG,Shen QU
DOI: https://doi.org/10.3969/j.issn.1005-8001.2014.06.012
2014-01-01
Abstract:Objective To evaluate virtual touch tissue quantification(VTTQ)for differentiating benign and malignant thyroid nodules.Methods 50 patients with 62 pathologically proven benign(30)and malignant(32)thyroid nodules underwent conventional ultrasound and VTIQ examinations.The nodules were divided into two groups of≤10 mm and>10 mm.Shear wave velocities(SWVs) of benign and malignant nodules and surrounding tissues were measured.The receiver operating characteristic curve(ROC)was used to assess the value of VTIQ in differentiating benign and malignant nodules.Areas under the curve(AUC)were compared between the two groups.Results The SWVs between benign nodules and surrounding tissues,between surrounding tissue of benign and malignant nodules were not significantly different(P=0.355,0.164)whereas the SWVs of malignant nodules were significantly higher than that of surrounding tissues(P=0).The AUC were 0.951 for nodules≤10 mm and 0.784 for nodules>10 mm.At SWV cut-off values of 2.53 m/s for nodules≤10 mm and 2.56 m/s for nodules>10 mm,the accuracy was 85.7%and 77.8%,sensitivity was 91.3%and 88.9%, specificity was 75.0%and 77.2%,positive predictive value was 87.5%and 61.5%,negative predictive value was 81.8%and 92.8%, odds ratio was 31.5 and 20.8,respectively.Conclusion VTIQ is valuable in differentiating benign from malignant thyroid nodules.