Note: Calibration Of Majority Isotopes For Enriched And Depleted Uranium Fission Chambers By Using The Elimination Method With Fast Neutrons

J G Qin,L An,X X Lu,T H Zhu,L Jiang,M Wang,B Yang
DOI: https://doi.org/10.1063/1.5052617
IF: 1.6
2018-01-01
Review of Scientific Instruments
Abstract:Calibrated miniature pulse fission chambers (MPFCs) can be used for absolute measurement of the fission reaction rate in neutronic experiments. Absolute measurements require the effective number of fissionable atoms (ENFAs) in the coating of the chambers. An elimination method was proposed to calibrate the MPFCs embodying highly enriched and depleted uranium, using 14.75 MeV fast neutrons from the D-T reaction. The ENFAs of U-235 in enriched uranium MPFC and U-238 in depleted uranium MPFC are 8.39 x 10(18) and 9.55 x 10(18), with the uncertainties of 5.27% and 4.76%, respectively. Published by AIP Publishing.
What problem does this paper attempt to address?