Enhanced Ultrasonic Flaw Detection Using an Ultra-high Gain and Time-dependent Threshold.

Yongfeng Song,Joseph A. Turner,Zuoxiang Peng,Chao Chen,Xiongbing Li
DOI: https://doi.org/10.1109/tuffc.2018.2827464
2018-01-01
Abstract:In an attempt to improve the ultrasonic testing capability of a conventional C-scan system, a flaw detection method using an ultrahigh gain is developed in this paper. A time-dependent threshold for image segmentation is applied to identify automatically material anomalies present in the sample. A singly scattered response model is used with extreme value statistics to calculate the confidence bounds of grain noise. The result is a time-dependent threshold associated with the grain noise that can be used for segmentation. Ultrasonic imaging experiments show that the presented method has advantages over a traditional fixed threshold approach with respect to false positives and missed flaws. The results also show that a low gain is adverse to the detection of microflaws with subwavelength dimensions. The forward model is expected to serve as an effective tool for the probability of detection of flaws and the inspection of coarse-grained materials in the future.
What problem does this paper attempt to address?