Transient Detonation Temperature Measurement of Explosives Using Spectroscopic Method

XL Zhou,Y Li,ZL Liu,CX Lu,JD Wang,Y Cao
DOI: https://doi.org/10.3321/j.issn:1000-0593.2003.05.041
2003-01-01
Spectroscopy and spectral analysis
Abstract:Based on the principle of double lines of atomic emission spectroscopy, a measurement system of transient optic fiber spectroscopy to determine the detonation temperature of explosives has been designed. In this method, the spectral signal of explosives detonation is transferred into the measurement system with a telescope and optical fiber, and collected by multichannel transient record. Its time resolution can reach as high as 0.1 mus. The wavelengths of the two spectral lines are Cu 1 510.5 and Cu 1 521.8 run, respectively. This temperature measurement system is simple and effective for detonation temperature measurement. Through the measurement of detonation spectral signal of the explosive, the transient detonation temperature-time distribution plots were obtained using this temperature measurement system.
What problem does this paper attempt to address?