Abstract:A remote-sensing high-temperature transient measurement system of double lines of atomic emission spectroscopy with telescope was used to measure the explosion temperature of explosive. The time resolution of the measurement system can achieve 0.1μs. The explosion temperature of Thermo-haric Explosive (TBE) and TNT were measured by this remote sensing method under the same conditions, and the distributing curves of temperature vs. time were obtained. The experimental result of TBE was compared with that of TNT. There are two temperature peaks of 2300 K and 2050 K corresponding with the first and second phase of explosive reaction of TBE respectively, while only one temperature peak of 2200 K appears when TNT explodes. The duration of high temperature higher than 1900 K of TBE is 2-3 times that of TNT.