A Magnetic Domain Spots Filtering Method with Self-Adapting Threshold Value Selecting for Crack Detection Based on the MOI

Yuhua Cheng,Lulu Tian,Chun Yin,Xuegang Huang,Libing Bai
DOI: https://doi.org/10.1007/s11071-016-2918-7
IF: 5.741
2016-01-01
Nonlinear Dynamics
Abstract:The paper proposes a method for crack detection using the magnetic optic image. It presents a way to filter the magnetic domain spots based on the image segmentation method utilizing the connectivity principle of image. As the area of the crack is much bigger than the magnetic domain spots and there is a mutation in the point, whose normalized slope is beyond \(45^\circ \), between the crack and the magnetic domain spots after sorting the area value of them, the machinery could filter the magnetic domain spots. In order to filter the spots, how to select the threshold is very important. The paper presents a self-adapting selection method to choose the threshold which based the pixel filling model. There would be a fast changing point of the filling area curve when the area increases. There is a corresponding filling value that is considered as the good threshold. Based on the features, the detecting system can recognize the crack clearly and the results would confirmed it.
What problem does this paper attempt to address?