Improving the accuracy of a dual-comb interferometer by suppressing the relative linewidth

Zhu Zebin,Xu Guangyao,Ni Kai,Zhou Qian,Wu Guanhao
DOI: https://doi.org/10.1088/1361-6501/aaa50b
IF: 2.398
2018-01-01
Measurement Science and Technology
Abstract:We present a compact system of synchronization for two fiber-based optical frequency comb lasers. We use a free- running continuous wave laser as an intermediary to obtain the relative noise of two combs and employ an intra-cavity electro-optic modulator (EOM) to achieve active phase feedback for fast synchronization. The EOM bandwidth is 150 kHz and the relative linewidth is suppressed markedly from 300 kHz to sub-hertz values. The relative effective timing jitter of the two pulse trains is also decreased from 680 fs to 25 fs. The proposed method shows promise for developing a high-performance, low-cost, fiber-based dual-comb interferometer for ranging or spectroscopy.
What problem does this paper attempt to address?