Vernier Microcombs for Integrated Optical Atomic Clocks

Kaiyi Wu,Nathan P. O'Malley,Saleha Fatema,Cong Wang,Marcello Girardi,Mohammed S. Alshaykh,Zhichao Ye,Daniel E. Leaird,Minghao Qi,Victor Torres-Company,Andrew M. Weiner
2023-09-22
Abstract:CMOS-compatible Kerr microcombs have drawn substantial interest as mass-manufacturable, compact alternatives to bulk frequency combs. This could enable deployment of many comb-reliant applications previously confined to laboratories. Particularly enticing is the prospect of microcombs performing optical frequency division in compact optical atomic clocks. Unfortunately, it is difficult to meet the self-referencing requirement of microcombs in these systems due to the $\sim$THz repetition rates typically required for octave-spanning comb generation. Additionally, it is challenging to spectrally engineer a microcomb system to align a comb mode with an atomic clock transition with sufficient signal-to-noise ratio. Here, we adopt a Vernier dual-microcomb scheme for optical frequency division of a stabilized ultranarrow-linewidth continuous-wave laser at 871 nm to a $\sim$235 MHz output frequency. In addition to enabling measurement of the comb repetition rates, this scheme brings the freedom to pick comb lines from either or both of the combs. We exploit this flexibility to shift an ultra-high-frequency ($\sim$100 GHz) carrier-envelope offset beat down to frequencies where detection is possible and to place a comb line close to the 871 nm laser - tuned so that if frequency-doubled it would fall close to the clock transition in $^{171}$Yb$^+$. Moreover, we introduce a novel scheme which suppresses frequency noise arising from interferometric phase fluctuations in our dual-comb system and reduces the frequency instability down to our measurement limit. Our dual-comb system can potentially combine with an integrated ion trap toward future chip-scale optical atomic clocks.
Optics
What problem does this paper attempt to address?
This paper primarily discusses the issue of optical frequency division using a Vernier dual microcomb system in integrated photonic atomic clocks. Traditional microcombs, due to their terahertz-level repetition rates, make self-referencing and frequency division challenging. However, the Vernier dual microcomb approach resolves this difficulty. In the paper, researchers combined a primary microcomb with a broadband auxiliary microcomb on a silicon nitride platform, successfully dividing the frequency of a 871 nm ultra-narrow linewidth continuous-wave laser to an RF output of approximately 235 MHz. This laser design can be doubled in frequency to approach the clock transition frequency of ytterbium ions (171Yb+), promising to enhance frequency stability. With the Vernier dual microcomb system, researchers were able to select lines from either or both microcombs to achieve a wider range of frequency and signal-to-noise ratio adjustments. They also proposed a new method to suppress frequency noise caused by phase fluctuations of interference in the dual comb system, thereby reducing frequency instability. Moreover, the dual comb structure mentioned in the paper could potentially be integrated with ion traps, offering possibilities for future chip-scale photonic atomic clocks. The key contribution of the paper lies in demonstrating a flexible and universal microcomb platform that overcomes challenges previously faced by microcomb-based systems in realizing chip-scale optical atomic clocks. The frequency division through the dual microcomb system not only allows for the detection of high-frequency carrier-envelope offset shifts but also enables frequency conversion for various atomic transitions, paving the way for the development of future optical clocks.