Decoupling Analysis of a Six-Dimensional Force Sensor Bridge Fault.

Guangyu Hu,Qing Gao,Huibin Cao,Hongqing Pan,Feng Shuang
DOI: https://doi.org/10.1109/access.2017.2784485
IF: 3.9
2017-01-01
IEEE Access
Abstract:This paper introduces the structural characteristics of a 6-D force sensor based on an E-type membrane, analyzes the calibration results of each bridge, and determines the coupling relationship between bridges of a sensor. In the case that a sensor has no fault in its bridges, a decoupling matrix is calculated by identifying a linear decoupling model. In the case that the fault happens, a linear neural network method is used to discard the faulty bridge to calculate the reduced-dimensional decoupling matrix, and the BP neural network nonlinear method is used to compensate the faulty bridge signal for fault-tolerant decoupling. Simulation results indicate that the reliability of the sensor under the fault condition has been significantly improved.
What problem does this paper attempt to address?