Improved infiltration rate determination method for interlocking-block permeable pavements using standard ASTM test apparatus

B. Zhu L. Chu T. F. Fwa a School of Forensic Science and Technology,Criminal Investigation Police University of China,Shenyang,People's Republic of Chinab School of Future Transportation,Chang'an University,Xi'an,People's Republic of Chinac School of Future Transportation,Chang'an University,Xi'an,People's Republic of Chinad National University of Singapore,Singapore,Singapore
DOI: https://doi.org/10.1080/10298436.2024.2423216
2024-11-09
International Journal of Pavement Engineering
Abstract:Current standard methods of measuring permeability of interlocking-block permeable pavements (IBPPs) do not correctly measure the actual infiltration rates of IBPPs. The test results vary with test area size and location. In this study, employing the standard ASTM-1781 test apparatus, an improved procedure that adopts an experiment-based numerical approach is developed to overcome the problem. It involves the following steps: (i) Perform falling-head infiltration tests using ASTM-1781 apparatus to obtain infiltration flow data; (ii) Develop computational fluid dynamic (CFD) finite-volume models for different infiltration test conditions; and (iii) Apply appropriate finite-volume model to calculate the effective IBPP infiltration rate under any given surface water depth on the IBPP. Experimental tests were conducted to validate the proposed method.
construction & building technology,engineering, civil,materials science, characterization & testing
What problem does this paper attempt to address?