Research on Thread Seal Failure Mechanism of Casing Hanger in Shale Gas Wells and Prevention Measures

Yisheng Mou,Yonggang Xie,Fengqi Wei,Han Zhao,Lihong Han
DOI: https://doi.org/10.3390/pr12061253
IF: 3.5
2024-06-19
Processes
Abstract:The strength and sealing failure of the connecting thread of the casing head mandrel hanger causes huge economic losses. One of the major challenges is the thread seal failure mechanism of the casing hanger in the wellhead during pressure testing in shale gas wells. In order to analyze the failure causes of connecting threads and put forward improvement measures, a typical case of a well accompanied by a hanger seal failure is analyzed in this paper, and a series of material tests are carried out. The microstructure and mechanical properties of casing materials and hanger materials could meet the field requirements. It is concluded that both the hanger material and casing material are characterized with significant ductile fracture. A three-dimensional model of the hanger and casing system is established, and the mechanical behavior is calculated for the connecting thread under different working conditions. The results showed that the connection degree of the hanger–casing is insufficient at the torque recommended by the manufacturer because of the difference in wall thickness between the box thread of the hanger and the box thread of the joint according to the connection degree of the coupling casing. It is seen that the high contact pressure ring of zone three on the sealing surface plays an effective sealing role under the manufacturer's recommended torque (20,465 N·m). Finally, when the torque is increased by 25%, the maximum contact pressure between the pin thread of the casing and the box thread of the hanger can fully meet the internal pressure from the wellbore pressure test and the internal pressure strength required for subsequent operations.
engineering, chemical
What problem does this paper attempt to address?
The paper mainly studies the mechanism of casing hanger connection thread sealing failure in shale gas wells and its preventive measures. During the pressure testing process of shale gas wells, the strength of the casing hanger connection thread and the sealing failure result in significant economic losses. Specifically, the paper analyzes a typical case of hanger seal failure and conducts a series of material tests to determine whether the casing material and hanger material meet the site requirements. The study found that both the hanger and casing materials exhibit significant toughness fracture characteristics. A three-dimensional model of the hanger and casing system was established, and the mechanical behavior of the connection thread under different operating conditions was calculated. The results show that under the recommended torque by the manufacturer, the connection between the hanger and the casing is insufficient due to the difference in wall thickness between the hanger's box thread and the joint's box thread. However, when the torque is increased by 25%, the maximum contact pressure between the casing's external thread and the hanger's internal thread can fully meet the internal pressure brought by the wellbore pressure testing and the internal pressure strength required for subsequent operations. In conclusion, through experiments and theoretical analysis, the paper reveals the causes of casing hanger connection thread sealing failure in shale gas wells and proposes improvement measures, which are of great significance for improving the safety and economy of shale gas wells.