Axial compressive behavior of pre-damaged concrete-filled square steel tube columns repaired with section circularization and CFRP composites

Kang Zhao,Zhongjun Hu,Boxin Wang,Weicheng Liao,Yan Xu
DOI: https://doi.org/10.1016/j.tws.2024.111606
IF: 5.881
2024-01-29
Thin-Walled Structures
Abstract:This study focused on repair treatments for the effective reuse of damaged concrete-filled square steel tube (CFSST) columns with carbon fiber-reinforced polymer (CFRP) composites. Forty specimens were designed to investigate the effects of pre-damage levels, section circularization, and the number of CFRP layers on the compressive behavior of the repaired CFSST columns. Test results indicated that the method of section circularization and CFRP wrapping effectively restored the degraded initial axial stiffness of the pre-damaged CFSST columns and increased the ultimate bearing capacity of the pre-damaged CFSST columns by 49–180 % compared to their undamaged condition. Considering the influence of the pre-damage level and the contribution of section circularization, the ultimate bearing capacity calculation model was suggested for predicting the compressive behavior of the repaired CFSST columns. The experimental results and collected test data have well verified the accuracy and applicability of the calculation model.
engineering, mechanical,mechanics, civil
What problem does this paper attempt to address?