Abstract:This paper describes an experimental investigation on open-loop and closed-loop control of earthquake response of adjacent buildings coupled with semi-active magneto-rheological (MR) dampers. A 1:15 scaled adjacent structural system consisting of an eight-story building model and a five-story building model was tested on a shaking table with open-loop control and closed-loop control strategies, respectively. An MR damper with large stroke is specifically designed for this purpose. The MR damper is used to interconnect the two structural models at different floors for open-loop and closed-loop control. The control experiments are also conducted on the shaking table that excites sweep sine excitation and El Centro earthquake excitation at the base. In the closed-loop control testing, semi-active response control with the MR damper as actuator is implemented using the dSPACE DS1005 real-time control system. A stochastic optimal control strategy developed by the authors is applied through the dSPACE system and its MATLAB environment to accomplish real-time semi-active control from the measurement of displacement responses at each floor. Different MR damper installation locations are introduced in the testing for a comparative study. The experimental results demonstrate that the semi-active MR damper can offer appreciable seismic response mitigation for adjacent buildings in both open-loop and closed-loop control modes.