Effect of reservoir on controllable loop thermosyphon

Cao, Jingyu,Pei, Gang,Su, Yuehong,Munir, Anjum,Li, Jing,Wang Yunyun
2016-01-01
Bulgarian Chemical Communications
Abstract:The controllable loop thermosyphon (CLT) has the potential to be utilized in various applications, including cool-storage refrigerators powered by solar energy and electricity with the time-of-use price policy. An active control method can be achieved by interrupting the two-phase natural circulation flow of CLTs. However, the precise temperature control performance of CLTs under active control depends on the system design and should be optimized. In this study, CLTs with and without a reservoir were designed and tested. Valves were added to the vapor and liquid lines. Therefore, three control modes were available to start and stop the heat transfer process of the CLTs. A series of experiments was conducted to compare the start-stop and heat transfer performances of the two CLTs at various R134a fill ratios and heat sink temperatures. The heat transfer performance of the CLT with a reservoir was more stable than that of the CLT without a reservoir. The reservoir degraded the start-stop performance of CLT in control mode A. The start-stop performances of the two CLTs were similar in control mode C. The CLTs in control mode C started up in approximately 20-25 s and stopped in about 70-80 s. Results revealed that an optimal system design could be selected under different application backgrounds.
What problem does this paper attempt to address?