Development and Calibration of the Moon-based EUV Camera for Chang'e-3

Bo Chen,Ke-Fei Song,Zhao-Hui Li,Qing-Wen Wu,Qi-Liang Ni,Xiao-Dong Wang,Jin-Jiang Xie,Shi-Jie Liu,Ling-Ping He,Fei He,Xiao-Guang Wang,Bin Chen,Hong-Ji Zhang,Hai-Feng Wang,Xin Zheng,Shu-Lin E,Yong-Cheng Wang,Tao Yu,Liang Sun,Jin-Ling Wang,Zhi Wang,Liang Yang,Qing-Long Hu,Ke Qiao,Zhong-Su Wang,Xian-Wei Yang,Hai-Ming Bao,Wen-Guang Liu,Zhe Li,Ya Chen,Yang Gao,Hui Sun,Wen-Chang Chen
DOI: https://doi.org/10.1088/1674-4527/14/12/013
2014-01-01
Research in Astronomy and Astrophysics
Abstract:The process of development and calibration for the first Moon-based extreme ultraviolet (EUV) camera to observe Earth's plasmasphere is introduced and the design, test and calibration results are presented. The EUV camera is composed of a multilayer film mirror, a thin film filter, a photon-counting imaging detector, a mechanism that can adjust the direction in two dimensions, a protective cover, an electronic unit and a thermal control unit. The center wavelength of the EUV camera is 30.2 nm with a bandwidth of 4.6 nm. The field of view is 14.7 degrees with an angular resolution of 0.08 degrees, and the sensitivity of the camera is 0.11 count s(-1) Rayleigh(-1). The geometric calibration, the absolute photometric calibration and the relative photometric calibration are carried out under different temperatures before launch to obtain a matrix that can correct geometric distortion and a matrix for relative photometric correction, which are used for in-orbit correction of the images to ensure their accuracy.
What problem does this paper attempt to address?