Stable Operation of the 2 K Cryogenic System for the Superconducting Accelerator at Peking University

Lin,Hao Jian-Kui,Xie Hua-Mu,Quan Sheng-Wen,Wen Xiao-Dong,Zhao Kui,Liu Ke-Xin
DOI: https://doi.org/10.1088/0256-307x/30/8/080702
2013-01-01
Chinese Physics Letters
Abstract:A superconducting energy recovery linac test facility (PKU-SETF) was built at Peking University, and a 2K cryogenic system, which is the first closed-loop 2K cryogenic system for a superconducting accelerator in China, was constructed for the 1.3 GHz 3+1/2 cell dc-SRF injector. The main accelerator consists of two nine-cell TESLA-type superconducting cavities of the PKU-SETF The commissioning and stable operation of this 2 K cryogenic system was carried out. A helium pressure stability of better than ±0.1 mbar and a total refrigeration capacity of 65 W at a temperature of 2K was reached.