Compact Grating Displacement Measurement System with a 3 × 3 Coupler

Chunhua Wei,Shuhua Yan,Cunbao Lin,Zhiguang Du,Guochao Wang
DOI: https://doi.org/10.3788/col201513.051301
IF: 2.56
2015-01-01
Chinese Optics Letters
Abstract:We present a compact displacement measurement system possessing the capability of nanometer-scale precision.On basis of integrating single grating with 3 × 3 coupler for phase shift in interference signal, the present scheme features advantages of simple structure, convenient alignment, and insensitivity to air turbulence. Linear comparisons between our system and HP5530 show a residual error less than 81 nm during step motions along a10 mm round-trip, and a discrepancy less than 15 nm in the case of 200 μm movement. We also demonstrate a measurement stability test in a duration of 300 s, which shows the proposed scheme potentially performs better than HP5530 in terms of long-term stability.
What problem does this paper attempt to address?