The Correction for Using X-Cut Quartz Transducers in Shpb

P. Zhao,Y. Lin,F. Lu,J. Li,R. Chen,G. Sun
DOI: https://doi.org/10.1051/dymat/2009087
2009-01-01
Abstract:A correction method for using X-cut quartz transducers in SHPB was proposed. We analyzed the error factors from the piezoelectric equation. Using numerical simulation results, we found the major error. A simple expression was built, and a set of copper standard samples was tested for calibrating the influence coefficient. The influence coefficient was validated in Al tests. With the correction method, a kind of low density polyurethane foam was investigated by SHPB using the quartz transducer. Experimental results showed that the error correction made the X-cut quartz transducer use in SHPB more convenient and valid.
What problem does this paper attempt to address?