Abstract:An important topic regarding industrial application of non-thermal plasma technique: increasing the overall energy efficiency is discussed in this paper. The total energy efficiency can be subdivided into 4 steps. A new system has been developed to look at several of these steps. Measurements were performed regarding the "second step" in the energy efficiency optimization: matching between pulse source and reactor. It was shown that by increasing the voltage, higher energy efficiencies could be obtained. Also matching the reactor capacitance to the output impedance of the source and the rise-time of the generated pulses was shown to be beneficial to energy efficiency. At this moment the best efficiency (from energy storage to reactor) was about 60%. Implementation of a new pulse transformer and a DC bias voltage will result in higher efficiencies (similar to 95%, as was already observed in the past)