Recovery Process of Wall Condition in KSTAR Vacuum Vessel after Temporal Machine-Vent for Repair

Kwang Pyo Kim,Suk-Ho Hong,Hyunmyung Lee,Jae-in Song,Nam-Yong Jung,Kunsu Lee,Yong Chu,Hakkun Kim,Kaprai Park,Yeong-Kook Oh
DOI: https://doi.org/10.1016/j.fusengdes.2015.07.001
IF: 1.905
2015-01-01
Fusion Engineering and Design
Abstract:Efforts have been made to obtain vacuum condition that is essential for the plasma experiments. Under certain situations, for example, the vacuum vessel should be vented to repair in-vessel components such as diagnostic shutter, exchange of window for diagnostic equipment, and PFC damaged by high energy plasma. For the quick restart of the campaign, a recovery process was established to make the vacuum condition acceptable for the plasma experiment. In this paper, we present the recovery process of wall condition in KSTAR after temporal machine-vent for repair. It is found that an acceptable vacuum condition has been achieved only by plasma based wall conditioning techniques such as baking, GDC, and boronization. This study was that the proper recovering method of the vacuum condition should be developed according to the severity of the accident. (C) 2015 Published by Elsevier B.V.
What problem does this paper attempt to address?