Occlusive thrombosis in the rabbit auricular vein in vivo targeted by induction of intralumenal cavitation using HIFU and ultrasound contrast agent

andrew a brayman,juan tu,thomas matula,lawrence a crum,joo ha hwang,michael b kimmey
DOI: https://doi.org/10.1121/1.4788511
2005-01-01
Abstract:Hypotheses tested: (1) inertial cavitation [IC] could be induced in the venous lumen in vivo by combined use of intravascular microbubble contrast agent and transcutaneous application of 1-MHz high intensity focused ultrasound [HIFU] of very low duty factor, and that IC activity could be detected and quantified in vivo as in earlier in vitro studies via passive cavitation detection methods; (2) robust IC activity would damage the venous endothelium in treated regions; (3) endothelial damage would be proportional to the IC dose developed in the region; (4) severe local endothelial damage alone may be sufficient to induce occlusive thrombosis, or may sensitize the region to low systemic doses of prothrombotic agents, and (5) biologically significant temperature rises and attendant thermal bioeffects in the vessel and perivascular tissues would not occur, even under the highest amplitude acoustic conditions applied. Each hypothesis was supported by the data. The principal result was that under treatment conditions involving very high peak negative acoustic pressures and contrast agent, treated areas thrombosed acutely but non-occlusively. When fibrinogen was administered locally after such treatment, occlusive thrombi formed acutely and only in the treated region, a response observed with none of the other treatments.