Determining Inertial Measurement Unit Placement for Estimating Human Trunk Sway While Standing, Walking and Running.

Bo Yu,Tian Bao,Dingguo Zhang,Wendy Carender,Kathleen H. Sienko,Peter B. Shull
DOI: https://doi.org/10.1109/embc.2015.7319431
2015-01-01
Abstract:Inertial measurement units (IMU) are often used to estimate medial-lateral (M/L) trunk sway for assessing and treating gait disorders, and IMU sensor placement is an important factor effecting estimation accuracy. This study tracked multi-segment spine movements during standing and ambulation tasks to determine optimal IMU placement. Ten young healthy subjects, wearing markers placed along the spine, left/right acromion, and left/right posterior superior iliac spine performed standing and walking trials in a motion capture laboratory. Results showed that movement at the spine location T7-T8 most closely matched the clinical definition of M/L trunk sway for standing trials (0.5 deg error) and at the spine location T9-T10 for walking trials (1.0 deg error), while movement at the lower spine L2-L4 tended to be the least accurate for standing and ambulation tasks (1.5 deg error and 4.0 deg error, respectively). Based on these results, a second study was performed to develop and validate a trunk sway estimation algorithm during walking trials with a single optimally-placed IMU. IMU trunk sway estimation was compared to the clinical definition of trunk sway from motion capture markers and showed root-mean-square errors of 2.5 deg and peak trunk sway errors of 2.0 deg. The results of this study suggest that IMUs should be placed on the mid-back to reduce errors associated with spine movements not matching clinically-defined M/L trunk motion.