Robustness Analysis and Experimental Validation of a Fault Detection and Isolation Method for the Modular Multilevel Converter

shuai shao,Watson, A.J.,Clare, J.C.,patrick w wheeler
DOI: https://doi.org/10.1109/TPEL.2015.2462717
IF: 5.967
2016-01-01
IEEE Transactions on Power Electronics
Abstract:This paper presents a fault detection and isolation (FDI) method for open-circuit faults of power semiconductor devices in a modular multilevel converter (MMC). The proposed FDI method is simple with only one sliding-mode observer (SMO) equation and requires no additional transducers. The method is based on an SMO for the circulating current in an MMC. An open-circuit fault of power semiconductor device is detected when the observed circulating current diverges from the measured one. A fault is located by employing an assumption-verification process. To improve the robustness of the proposed FDI method, a new technique based on the observer injection term is introduced to estimate the value of the uncertainties and disturbances; this estimated value can be used to compensate the uncertainties and disturbances. As a result, the proposed FDI scheme can detect and locate an open-circuit fault in a power semiconductor device while ignoring parameter uncertainties, measurement error, and other bounded disturbances. The FDI scheme has been implemented in a field-programmable gate array using fixed-point arithmetic and tested on a single-phase MMC prototype. Experimental results under different load conditions show that an open-circuit faulty power semiconductor device in an MMC can be detected and located in less than 50 ms.
What problem does this paper attempt to address?