Comparison of PetrifilmTM AC and Pour plate techniques used for the heterotrophic aerobic bacterial count in water

Faith Mkhwanazi,Tshilidzi Mazibuko,Olivia Mosoma,Malefaso Rathebe,Mrudula Patel
DOI: https://doi.org/10.1093/femsle/fnae029
2024-04-29
FEMS Microbiology Letters
Abstract:Abstract Heterotrophic bacteria (HPC) are commonly found in water samples. While these bacterial counts do not necessarily indicate a health hazard, high counts provide a good indication of the efficiency of water disinfection and integrity of distribution systems. The aim of this study was to compare the PetrifimTM AC method to the Pour Plate technique for the testing of HPC in water samples. Artificially contaminated (192 samples) and natural water samples (25) were processed using two methods. Both methods accurately detected high, medium and low counts of HPC, producing average Z scores between -2 and + 2. Paired-wise student t-test and correlation coefficient showed nonsignificant differences between the results of two methods. Acceptable repeatability and reproducibility was obtained using both the methods. Uncertainty of measurement for PetrifilmTM AC and Pour Plate method was found to be 2.9% and 5.4% respectively. PetrifilmTM AC proved to be robust at 33 °C and 37 °C. In conclusion, PetrifimTM AC, which is easy to process, read and less time consuming, proved to be comparable to the conventional Pour Plate method in establishing HPC in water. In addition, PetrifimTM AC requires less space for the processing and incubation, generate small volume of waste for disposal and requires no equipment, except for the incubator.
microbiology
What problem does this paper attempt to address?
The problem this paper attempts to address is: comparing the performance of the Petrifilm™ AC method with the traditional pour plate method in the heterotrophic plate count (HPC) testing of water samples. Specifically, the study aims to verify whether the Petrifilm™ AC method can serve as an alternative to the traditional pour plate method for the total bacterial count in water samples. The study compares the following aspects: 1. **Accuracy**: Evaluating the accuracy of both methods at different concentrations (high, medium, low). 2. **Repeatability**: Assessing the repeatability of both methods by the same operator on the same day. 3. **Reproducibility**: Evaluating the reproducibility of both methods by different operators on different days. 4. **Measurement Uncertainty**: Calculating the measurement uncertainty of both methods. 5. **Robustness**: Assessing the performance of the Petrifilm™ AC method at different incubation temperatures (33°C and 37°C). 6. **Natural Sample Testing**: Testing actual water samples using both methods and comparing the results. Through these comparisons, the study aims to determine whether the Petrifilm™ AC method can provide results comparable to the traditional pour plate method in the heterotrophic plate count testing of water samples, and whether it offers greater simplicity and efficiency.