Development of fast cooling pulsed magnets at the Wuhan National High Magnetic Field Center.

Tao Peng,Quqin Sun,Jianlong Zhao,Fan Jiang,Liang Li,Qiang Xu,Fritz Herlach
DOI: https://doi.org/10.1063/1.4849195
IF: 1.6
2013-01-01
Review of Scientific Instruments
Abstract:Pulsed magnets with fast cooling channels have been developed at the Wuhan National High Magnetic Field Center. Between the inner and outer sections of a coil wound with a continuous length of CuNb wire, G10 rods with cross section 4 mm x 5 mm were inserted as spacers around the entire circumference, parallel to the coil axis. The free space between adjacent rods is 6 mm. The liquid nitrogen flows freely in the channels between these rods, and in the direction perpendicular to the rods through grooves provided in the rods. For a typical 60 T pulsed magnetic field with pulse duration of 40 ms, the cooling time between subsequent pulses is reduced from 160 min to 35 min. Subsequently, the same technology was applied to a 50 T magnet with 300 ms pulse duration. The cooling time of this magnet was reduced from 480 min to 65 min. (C) 2013 AIP Publishing LLC.
What problem does this paper attempt to address?