[+Gz Protection of the on Board Oxygen Generating System (OBOGS) and Anti-G Equipment].

Xi-chen Geng,Yan Xu,Hong Wang,Zhao Jin,Bao-hui Li,Gui-ding Yan
DOI: https://doi.org/10.3969/j.issn.1002-0837.2002.01.009
2002-01-01
Abstract:OBJECTIVE:To investigate the +Gz protection of the on board oxygen generating system (OBOGS) and anti-G equipment.METHOD:Physical and physiological tests of the OBOGS and anti-G equipment were accomplished using human centrifuge. +Gz tolerance of ten male subjects with or without the anti-G suit, pressure breathing for G (PBG) and OBOGS were determined.RESULT:The performance of the OBOGS and anti-G equipment fulfilled the requirements. The +Gz protections of the anti-G suit, PBG, and anti-G system were 2.08 G, 1.92 G, and 3.92 G, respectively.CONCLUSION:The +Gz protection of the OBOGS and anti-G equipment satisfy the performance requirements of high performance aircraft.