The influence of DC-link voltage control on the performance of active power filter

Yu Wang,Yunxiang Xie,Xiang Liu
DOI: https://doi.org/10.1109/APEC.2015.7104807
2015-01-01
Abstract:In this paper, the inherent influence of DC-link voltage controller on the steady-state compensation performance in three-phase four-wire shunt active power filter (APF) is investigated. In order to take into account both the DC-link voltage control characteristic and the steady-state compensation performance, an variable parameter DC-link voltage controller is proposed, in which the parameter will be varied according to the difference between the actual and reference DC-link voltage. Representative simulation and experimental results on the three-phase four-wire center-split shunt APF are presented to verify the analysis and also the feasibility and effectiveness of the proposed DC-link voltage controller.
What problem does this paper attempt to address?