Decomposing and Detecting of Generalized Reactive Current by Orthogonal Characteristics
DUAN Da-peng,JIANG Xiu-chen,SUN Cai-xin,ZENG Yi
DOI: https://doi.org/10.3969/j.issn.1003-6520.2007.10.041
2007-01-01
Abstract:Nonlinear circuit with probabilistic periodical voltage and current was defined as two vectors of H-dimensions Inner Product Space,then based on the S.Fryze's time-domain power theory,the current was decomposed into two components that were generalized active current and generalized reactive current,and the generalized active current component was similar to voltage in shape and phase only in peak value.Using the orthogonal characteristics between the two current components,the conductance proportion coefficient K between voltage and generalized active current was proposed.Furthermore,a novel detecting method of generalized reactive current and its simplified formula,which needs not coordinate transform,phase-locked loop and filter,was presented.This method can be extensively used in circuit with probabilistic periodical voltage and probabilistic load.At last,the detecting method was simulated under three situations including sinusoidal voltage-inductive load,sinusoidal voltage-nonlinear load and nonsinusoidal voltage-nonlinear load,moreover,it was compared with ip iq detecting method based on the instantaneous reactive power theory.Simulation results and numerical calculation verify the correctness and advantages of the proposed method.Decomposing and detecting method proposed in this paper was significant in power analysis and reactive power compensation due to its simple calculation and extensive use fields.