AVERAGE AND INSTANTANEOUS REACTIVE POWER OF NON-SINUSOIDAL CIRCUIT BASED ON HILBERT TRANSFORMATION

薛永端,徐丙垠,冯祖仁
DOI: https://doi.org/10.3321/j.issn:1000-1026.2004.12.008
2004-01-01
Abstract:There have been no widely accepted definitions of average and instantaneous reactive power for non-sinusoidal alternating-current circuit. A definition of reactive power for sinusoidal circuit is discussed. Then the definitions of average and instantaneous reactive power based on Hilbert transformation for non-sinusoidal circuit are presented. The average reactive power is defined as average power between current and voltage after Hilbert transformation. The instantaneous reactive power is defined as product of reactive component of current and voltage after Hilbert transformation. The reactive component of current is defined as projection of current on voltage after Hilbert transformation. These definitions satisfy the general requirements of power, conform to definitions and characteristics of average and instantaneous active power, and meet the requirements of average and directionality. An application example is given.
What problem does this paper attempt to address?