In Vitro Detection of Superoxide Anions Released from Cancer Cells Based on Potassium-Doped Carbon Nanotubes-Ionic Liquid Composite Gels

Xiao-Rong Li,Bo Wang,Jing-Juan Xu,Hong-Yuan Chen
DOI: https://doi.org/10.1039/c1nr11025j
IF: 6.7
2011-01-01
Nanoscale
Abstract:A newly developed electrochemical biosensor for the determination of superoxide anions (O-2(.-)) released from cancer cells using potassium-doped multi-walled carbon nanotubes (KMWNTs)-1-butyl-3-methylimidazolium hexafluorophosphate ([BMIM]PF6) ionic liquid composite gels is demonstrated. The KMWNTs-[BMIM]PF6 can electrocatalyze oxygen reduction to generate a strong current signal in neutral solution. Compared with KMWNTs without [BMIM]PF6 or MWNTs-[BMIM]PF6 composites, the KMWNTs-[BMIM]PF6 can enhance the oxygen reduction peak current by 6.2-fold and 2.8-fold, which greatly increases the detection sensitivity of oxygen. Then, O-2(.-) biosensors are fabricated by mixing superoxide dismutase (SOD) in the KMWNTs-[BMIM] PF6 gels via monitoring oxygen produced by an enzymic reaction between SOD/O-2(.-) without the help of electron mediators. The resulting biosensors show a linear range from 0.04 to 38 mu M with a high sensitivity of 98.2 mu A mM(-1),and a lower detection limit of 0.024 mu M. The common interferents such as hydrogen peroxide (H2O2), ascorbic acid (AA), uric acid (UA), and metabolites of neurotransmitters, do not interfere with the detection of O-2(.-). The proposed biosensor is tested to determine O-2(.-) in vitro and from liver cancer and leukemia cells and shows good application potential in biological electrochemistry.
What problem does this paper attempt to address?