Cobalt Phosphates Loaded into Iodine-Spaced Reduced Graphene Oxide Nanolayers for Electrochemical Measurement of Superoxide Generated by Cells
Zhuo Zou,Jie Chen,Zhuanzhuan Shi,Chengsong Yuan,Guangdong Zhou,Qian Liu,Hong Chen,Qingxin Zeng,Taotao Liang,Kang Lai Tang,Chang Ming Li
DOI: https://doi.org/10.1021/acsanm.1c00148
IF: 6.14
2021-03-22
ACS Applied Nano Materials
Abstract:Cobalt phosphate (Co<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub>) has been recognized as a biomimetic superoxide anion (O<sub>2</sub><sup>•–</sup>) sensing material, but there is a great challenge to achieve high sensitivity due to its relatively poor conductivity. Here, a unique nanostructure is synthesized by using iodine nanospacer-impregnated reduced graphene oxide (I-rGO) layers to nest Co<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub>. The role of iodine greatly enhances the density of nanoscale Co<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub> catalytic centers by separating reduced rGO layers while accelerating the interfacial electron transfer and followed transport through the directionally arranged conductive grapheme layers. The Co<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub>/I-rGO sensor delivers a very good selectivity with a higher sensitivity, shorter response time, and wider linear range than that of Co<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub>/rGO without the iodine nanospacers toward O<sub>2</sub><sup>•–</sup> detection, and also the reported Co<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub> nanorods work. Furthermore, the sensor was used to detect O<sub>2</sub><sup>•–</sup> generated by prostate cancer cells. This study holds promise for a high value nanoscale biomimetic sensor in practical clinical and bioresearch applications and also demonstrates a rational merit-hybrid nanocomposite design by offering critical contributions from individual components into the biomimetic sensing platform.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsanm.1c00148?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsanm.1c00148</a>.XPS analysis, contact angle test, comparison for the electrochemical oxidation behaviors of the prepared working electrodes, CVs of Co<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub>/I-rGO/GCE and Co<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub>/rGO/GCE at various scan rates, Nyquist plots, CVs of different ratios of Co<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub>, Plot of the dependence of the peak current on different pH values, and stability test of the Co<sub>3</sub>(PO<sub>4</sub>)<sub>2</sub>/I-rGO sensor (PDF) (<a class="ext-link" href="/doi/suppl/10.1021/acsanm.1c00148/suppl_file/an1c00148_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology