A Highly Sensitive <tex>$\boldsymbol{O}_{2}{}^{\bullet-}$</tex> Biosensor Based on PEDOT:PSS/SA Composite Conductive Hydrogel

Yuyang Yuan,Tianyu Li,Shiyi Xu,Zhichao Ye,Shanshan Zhang,Lu Fang,Bo Liang
DOI: https://doi.org/10.1109/SENSORS56945.2023.10325033
2023-01-01
Abstract:Superoxide anion (O <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">·−</sup> ) plays a vital role in the pathogenesis of many diseases, making it a biomarker of great value in early assessment of disease progression. However, due its short half-life, low concentration and rapid fluctuations, detecting O <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">·−</sup> poses significant challenges. In this study, we proposed an electrochemical biosensor based on a composite conductive hydrogel that enabled rapid and sensitive O <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">·−</sup> detection. The hydrogel synthesized with poly (3,4-ethylenedioxythiophene): poly (styrenesulfonate) (PEDPT:PSS) and sodium alginate (SA) exhibited good conductivity and mechanical properties. When applied for O <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">·−</sup> detection, the composite conductive hydrogel-based biosensor showed a linear range of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.011\sim 32.59\ \mu\mathrm{M}$</tex> , a sensitivity of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$9.383\ \mu\mathrm{A}\ \mu\mathrm{M}^{-1}\text{cm}^{-2}$</tex> and a detection limit of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$0.007\ \mu\mathrm{M}$</tex> , with robust anti-interference capabilities and stability. This innovative O <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">·−</sup> biosensor achieved high responsiveness at low concentrations and held promise for advancing O <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</inf> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">·−</sup> detection and facilitating early disease diagnosis.
What problem does this paper attempt to address?