Global calibration for multiple cameras in profile measurement system based on light-sectioning method

BoHua Zhao,Boxiong Wang,Xiuzhi Luo,XiaoAo Han
DOI: https://doi.org/10.3788/OPE.20111913.0197
2011-01-01
Abstract:A multi-camera global calibration method based on an LCD target and a solid target with edges is proposed. With the nonlinear polynomial mapping between the image coordinate of a camera and the world coordinate, the rectangular patterns as the carrier of calibration points are displayed on an LCD. And the camera calibration of each side of laser plane between the image coordinate and the corresponding laser-plane coordinate is achieved respectively by synchronizing calibration patterns displayed and sampled. One of the laser-plane coordinate systems is used as the standard coordinate system, with the other as the one to be converted. The intersection points of solid target edge and the laser-plane are used as the calibration points for obtaining a transformation matrix of standard coordinate system to the one to be converted. Global calibration and data fusion for all cameras are achieved in an unified world coordinate. An experiment on a standard block is performed with the three-dimensional surface measurement system calibrated by this method which shows that the relative error between the measured value and the true value for the contour height in a section is 0.052%.
What problem does this paper attempt to address?