A simple calibration procedure for structured light system
Huafen Luo,Jing Xu,Nguyen Hoa Binh,Shuntao Liu,Chi Zhang,Ken Chen
DOI: https://doi.org/10.1016/j.optlaseng.2014.01.010
IF: 5.666
2014-01-01
Optics and Lasers in Engineering
Abstract:The structured light system with a camera and a projector is widely used in various fields. However, the accurate calibration, which is crucial for a structured light system, is usually complicate and time-consuming, especially in the projector calibration stage. In addition, the calibration error of a projector is relatively bigger than a camera. Hence, a structured light system without the projector calibration can greatly reduce the system calibration error and simplify the calibration process. In this paper, a calibration method without projector calibration is proposed, in which the projector's line-of-sights serves as spatially vectors invariant to the environment. By introducing four reference planes and building look-up-tables for the camera-projector pixel correspondence, the 3D reconstruction of the system can be obtained without any projector's information. A series of experiments were performed to evaluate the proposed method, and it turned out that its accuracy is about 0.0925mm.