Calibration of a 3D Measurement System Having One Camera and One Projector

WEI Zhengliang,ZHONG Yuexian,YUAN Chaolong,JIAO Wei
DOI: https://doi.org/10.3321/j.issn:1000-0054.2009.02.012
2009-01-01
Abstract:Structured light 3D measurements can quickly and accurately reconstruct object surface once they are accurately calibrated. This paper presents a calibration method for a system having one camera and one projector. The camera calibration use the Tsai two-step method and non-linear optimization using a single plane calibration block with a pattern of white circular points on a black background. The projector is calibrated in the same way as a virtual camera by capturing the calibration points in the projecting plane using two-dimensional phase demodulation. Phase demodulation uses space-time coding based on unfolding of color stripes in pseudo random sequence and three-step phase shifting. The calibration is simple, convenient and automatic. The tests show that the calibration is very accurate.
What problem does this paper attempt to address?