Research on the calibration technique of proiector in structured light 3D measurement System

Zheng-liang WEI,Yue-xian ZHONG,Chao-long YUAN
DOI: https://doi.org/10.3321/j.issn:1002-1582.2009.02.008
2009-01-01
Optical Technique
Abstract:Projector calibration is one of the most basic in structured light 3D measurement consisted of one camera and one projector.The projector calibration technique is based on double-face calibration block.The up surface of the block with pattern of white circular points on black background is used to complete camera calibration by Tsai two-step method and non-linear optimization.The down surface of the block is white in uniform reflection condition,the projector projects two-dimensional line with high intensity to form characteristic points.There are two methods to solve the difficult problem that the three dimensional coordinates of the points are hard to achieve: one is according the result of camera calibration,the other is by cross-ratio with the pattern of circular points on up surface to get more effective input data.The calibration device is simple,the whole operation is convenient.The experiment results prove the accuracy of calibration is satisfied.