A Novel Topology of Fault-Tolerant Three-Phase Four-Switch Grid-Connected Inverter Based on Space Vector Hysteresis Control

Shi-ying HOU,Xing SONG,Tao SUN,Chuang ZHANG
DOI: https://doi.org/10.3969/j.issn.1674-3415.2011.21.026
2011-01-01
Abstract:Three-phase dual-buck-type grid-connected inverter is a new excellent topology and has important application value in the field of renewable power generation.In order to make the three-phase dual-buck-type grid-connected inverter can operate in fault-tolerant mode,a novel fault-tolerant three-phase four-switch grid-connected inverter is proposed as its operation topology after fault reconstruction to improve the system reliability.The space vector hysteresis control of the novel fault-tolerant topology is researched based on the equivalent analysis to make it can transmit high quality electric energy to grid and has good dynamic performance and steady state performance.Simulation results show that the inverter in space vector hysteresis control show good dynamic and static performance,which has very good inhibitory ability for input disturbances and grid voltage disturbance.The grid-connected current output is of high quality and the harmonic content is low.It can guarantee the reliable power supply after the trouble.
What problem does this paper attempt to address?