The performance of anoxic-Biostyr® (BAF) after backwashing during a filter run

Hongjie Wang,Wenyi Dong,Jie Liu,Lisha Liu
DOI: https://doi.org/10.1109/icbbe.2011.5781156
2011-01-01
Abstract:The performance of the anoxic-Biostyr ® biological aerated filter (A-BAF) and the headloss development of BAF after backwashing during a filter run were investigated by a bench-scale experiment. The results showed that the headloss of BAF generally increased in the operation time, and reached the maximum level at 84 h. There was no significant change in the effluent COD during the operation time, the average COD concentration of A-BAF effluent was about 34.7 mg/L, and the removal of SCOD took place mainly at the lower part of the BAF reactor. The removal rate of BAF decreased a little, and the NH 4 +-N of the effluent increased gradually from 0.5 mg/L to 2 mg/L. The effluent SS concentration was often blew 10 mg/L, except at the beginning of the filter run. © 2011 IEEE.
What problem does this paper attempt to address?