Research on Biomass, Activity and Performance of Up-Flow BAC Filtration System

CHANG Chih-Hsiang,LIAO Xiaobin,ZHANG Xiaojian,CHEN Chao,XIE Shuguang
DOI: https://doi.org/10.13209/j.0479-8023.2013.071
2013-01-01
Abstract:The spatial distribution of microbial biomass and activity in pilot-scale two-stage up-flow BAC filters were studied using lipid-P,plate colony count(HPC) and specific oxygen uptake rate(SOUR).Meanwhile,water qualities of the effluent were analyzed to evaluate the performance of BAC units.The results indicated that BAC filters could remove pollutants effectively,with the average removal efficiencies of 43.3 % for CODMn,45.7% for UV254,and 92.9 % for ammonia nitrogen,respectively.Furthermore,the removal of pollutants mainly occurred in of the top 400-mm GAC layer in the first-stage BAC filter.The content of lipid-P per unit volume media decreased from 7.49 to 4.86 nmol/cm3 and colony counts decreased from 2.26×107to 1.12×107 CFU/cm3,indicating that the amount of biomass decreased along flow path.The SOUR per unit volume media was around 10 2mg /(cm3.h) and had a different pattern of spatial distribution.In addition,the water quality of the effluent of up-flow BAC filters was biologically safe.
What problem does this paper attempt to address?