Abstract:Four types of beams, including reinforced concrete beam with the cover zone replaced by ultra high toughness cementitious composites (UHTCC) (thickness 15 mm if not counting the reinforcements, 50 mm if counting the reinforcements), reinforced concrete beam and reinforced UHTCC beam, were manufactured. The corrosion process of the reinforcing bars was artificially accelerated, inducing different degrees of corrosions. The time when the first crack occurred was recorded and the beams with different corrosion ratios of the reinforcing bars were tested under four-point bending for their load-deflection relations. The results showed that UHTCC could effectively restrict or delay the process of cracking of the cover due to corrosion expansion, alter the crack pattern, and delay the appearance of first corrosion expansion crack, thereby increasing the service life of reinforcement concrete structures or components. Meanwhile, the bending tests of the beams after accelerated corrosion showed that for beams with a cover of 50 mm UHTCC or completely replaced with reinforced UHTCC, respectively, the strength reduction and change of failure pattern after corrosion were both insignificant.