Influence of Fluoride-Containing Acidic Artificial Saliva on the Mechanical Properties of Nickel-Titanium Orthodontics Wires.
Jun Lin,Shujuan Han,Jiajun Zhu,Xiaoxiang Wang,Yuan Chen,Oliver Vollrath,Huiming Wang,Christian Mehl
DOI: https://doi.org/10.4103/0970-9290.107332
2012-01-01
Indian Journal of Dental Research
Abstract:OBJECTIVE This study aimed to investigate the influence of fluoride and an acidic environment on the mechanical properties of NiTi orthodontic wires (NiTiW) in artificial saliva. DESIGN A prospective laboratory investigation. SETTING Department of Stomatology, First Affiliated Hospital, Zhejiang University, Hangzhou, China. MATERIALS AND METHODS Commercial, round 0.016-inch NiTiW were immersed in 0% or 0.05% Natrium-Fluoride-containing artificial saliva at a pH of 4 or 6 for one or three days, respectively. NiTiW were examined with a three-point bending test, Vickers' microhardness tests and surface morphology observation (SEM). RESULTS A pH of 4 increased microhardness and decreased the three-point bending strength significantly (P≤0.05), whereas immersion time and fluoride concentration had no significant influence on the microhardness or on the three-point bending strength (P>0.05). When examining the test group NiTiWs after three days of immersion at a pH of 4 the SEM revealed a rough surface morphology, a damaged oxide layer and signs of corrosion. CONCLUSIONS The most influential factor for decreasing the unloading force and increasing the hardness seems to be the pH value, whereas immersion time and NaF addition do not have a major influence.