Experimental Study of the Electrohydrodynamically(EHD)-intensified Convection Heat Exchange Inside a Tube With Water Serving as the Working Medium

Zhang Tao
2011-01-01
Abstract:With water serving as the working medium,experimentally studied was the EHD(electrohydrodynamics) intensification mechanism controlling the convection heat exchange inside water jacket heat exchanger tubes.During the test,a direct current type high voltage electrode was mounted at the center of the water jacket heat exchanger tubes and the voltage of the electrode was within a range from DC 0~40 kV.A total of five groups of combined intensification test were performed at different flow rates and voltages respectively.The test results show that under the condition of different flow rates inside the tubes,the electric field all played intensification role to various extents on the heat conduction process inside the tubes.When the flow rate is 0.1 m3/h,the intensification coefficient of the electric field θ attains its maximal value,being up to 1.224.When the flow rate is 1.0 m3/h,the above-mentioned coefficient θ attains its minimal value,verifying that the electric field plays an intensification role on the convection heat conduction process with water serving as the working medium.It has also been found,however,that the intensification effectiveness achieved by the electric field enjoys a specific feature,which is susceptible to any change of the flow rate and at an identical flow rate,there exists an optimum intensification voltage value.It is not true that the higher the voltage value the better the intensification effectiveness.
What problem does this paper attempt to address?