High Resolution EUV Spectrometer Diagnostic System on EAST

ZHANG Wei,SHI YueJiang,WANG Qiuping,SHEN Yongcai,DU Xuewei,LI Yingying,FU Jia,WANG Fudi,Lü Bo,XU Jingcui,HE Xiaoye
2011-01-01
Nuclear Techniques
Abstract:A high resolution EUV spectrometer has been installed on EAST tokamak for plasma diagnostic.The system employs a concave varied line spacing groove holographic grating(1 200 grooves/mm at grating center) as dispersion elements,covering wavelength range of 50–500 ,with resolution of about 0.16  at 186.6 ,and monitoring up half of EAST plasma(0–450 mm).The time resolution is 20 ms and the spatial resolution achieves 50 mm.During the discharge with Ar injection,good spectra were obtained.Compared to the discharge without pumping Ar at all,the Ar spectrum was clearly observed.The time behavior of the C IV(312.42 ) intensity was analyzed.