Essential Improvement of the JT Cryocooler Working at Liquid Helium Temperature for Space: Efficient and Lightweight
Zhichao Chen,Shaoshuai Liu,Xinquan Sha,Yunwei Shen,Wang Yin,Zheng Huang,Lei Ding,Zhenhua Jiang,Zhihua Gan,Yinong Wu
DOI: https://doi.org/10.1016/j.ijrefrig.2024.08.006
IF: 4.14
2024-01-01
International Journal of Refrigeration
Abstract:Due to long lifetime, low level vibration and negligible electromagnetic interference, the Joule-Thomson (JT) cryocooler working at liquid helium temperature has been used in space. However, its cooling capacity and thermodynamic efficiency still need to be further improved under a certain mass limit, which is an essential improvement for space-efficient application of the JT cryocooler. Therefore, in this study, optimization design is carried out for a JT cryocooler working at liquid helium temperature. Based on the modification of Stirling cryocooler, pulse tube cryocooler and JT compressor, the developed JT cryocooler can provide a cooling capacity of 0.36 W at 4.18 K while the total input power and the total mass (without cryostat) are 1157 W and 26.8 kg, respectively. Compared with the literature research, it can be found that the developed JT cryocooler is suitable for space applications.