Analysis of detecting landfill leakage with in-situ 3D electrical method

XiuJun Guo,Peipei Yao,XiaoYu Huang
2011-01-01
Abstract:In-situ 3D electrical detecting system detects leak distribution and the conditions of leakage area by two different ways, that is, setting the electrodes-system at the bottom of the landfill and on the top of the landfill separately. This paper analyzes the differences between the two ways of testing, studies the key factors that impact the test, and finally finds the way to improve the testing methods. The results shows that: (1) 3D electrical detecting system under the membranes has higher accuracy for loopholes location. It has better resolving power for loophole shape and size. The conductivity of the leachate has a small effect on the potential distribution, but the detectability is greatly influenced by the strength of the supply current; (2) 3D electrical detecting system on the top of the landfill has its problems. It is not ripe with respect to the detectability. Increasing the power of the supply current, changing the distance of the remote electrode and improving the conditions of the electrodes ground connection can improve detection effect to a certain degree. To realize the leakage monitoring, placing 3D electrical detecting system under the impermeable layer during the construction period of the landfill is an effective measure.