Design and Experiment of the 3-D Electrical Resistivity Detecting System for Monitoring Underground Soil Contaminated by Landfill Leachate

尚浩,郭秀军,王仙丽,孟庆生
DOI: https://doi.org/10.3969/j.issn.1004-2903.2010.04.042
2010-01-01
Abstract:The electrical resistivity of soil layers always vary if they are contaminated by the leakage of landfill.An insitu electrical resistivity detecting system was designed to investigate the contaminated area at in-use and abandoned waste disposal site.Electrodes have been set as a grid below the HDPE membrane during the period of waste disposal construction.The sampling device can control those electrodes to beget the DC electrical field and measure electrical potential.The electrical resistivity map of the soil layers can be made in this way.With the contrast of resistivity maps measured at different times, leaks in geomembrances and the diffusion of leachate plume in soil layers can be detected and monitored.Therefore, we can take some measures to prevent pollution as soon as possible.The experimental results in lab show the resistivity of contaminated soil layers always declines with the increasing of leachate, the low-resistivity abnormal area on the apparent resistivity map can change with the diffusion of leachate plume and the size of the abnormal area may be consistent with the contaminated area.With the installation of this system, an intelligent and green landfill can be achieved.
What problem does this paper attempt to address?