Experiment of Monitoring Underground Aquifers Contaminated by Leachate of Landfill and Remation with 3-D Electrical Method

GUO Xiu-jun,WEI li,JIA Yong-gang,HUANG Xiao-yu
DOI: https://doi.org/10.3969/j.issn.1004-2903.2006.02.047
2006-01-01
Abstract:In order to discuss effective means of monitoring the dynamic diffusing process of polluted zone of underground aquifers caused by infiltration of landfill leachate and their renovating process,a three-dimensional electro-monitoring system is devised to stimulate the processes in laboratory.Experimental results indicate that the diffusing process of leachate in the aquifer behaves as the dynamic change of low-resistivity abnormal zone on electrical resistivity sections obtained in different periods of time.Pollution level,diffusing velocity and direction can be known from contrast analysis of such a change.The renovating process behaves as the increase of apparent electrical resistivity and change of abnormal characteristics distribution on electrical resistivity sections with the decreasing of pollutant content.The experimental results bear great significance in investigating present situations of underground aquifers polluted by landfill leachate as well as in dynamic monitoring the polluting and renovating process.
What problem does this paper attempt to address?