The Injection Efficiency Measurement and Analysis for Central Region Model Cyclotron.

Hongjuan Yao,Zhenguo Li,Tao Ge,Longcheng Wu,Fengping Guan,Yinlong Lv,Zhenhui Wang,Gengshou Liu,Tianjue Zhang,Hongru Cai
DOI: https://doi.org/10.1063/1.3310277
IF: 1.6
2010-01-01
Review of Scientific Instruments
Abstract:At the China Institute of Atomic Energy, a central region model cyclotron has been constructed, which is dedicated for various experimental verifications to study beam properties. The design features of the ion source and injection line have already been described in other papers. We shall report here the results of the initial beam tests. A wire scanner is employed in the injection line to measure beam transverse sizes and these data can be used to fit the phase plane parameters after the ion source. Based on the beam tests results, the ion source built in 2003 has been improved recently. The improvement is mainly due to the repair of the multicusp field. From the ion source to the exit of the inflector, a transmission efficiency of 93% has been obtained for a continuous and low current input beam. It is also described here the experimental arrangement and the results.
What problem does this paper attempt to address?